Your storefront works harder than any other part of the building. It takes wind off the lake, salt from the sidewalk, and a door that opens hundreds of times a day. Most failures start small: a closer that slams, a sealant joint that cracks, a threshold that ices up.
Walk the front of your building in spring and fall with this list. It takes about twenty minutes.
The Glass
An edge chip on tempered glass is worth a call. Tempered glass is strong across its face but vulnerable at the edge, and a chip there can turn into a full break.
- Chips or cracks, especially at edges and corners
- Fog or haze between panes of insulated glass
- Scratches or etching from cleaning or vandalism
- Peeling window film or old lettering adhesive
- The small safety-glazing mark in the corner of door glass
Framing and Sealant
Aluminum storefront framing is built to let small amounts of water in and drain it back out through weep holes. When those holes clog with dirt or ice, water goes somewhere else, usually inside.
- Sealant joints that are cracked, hard, or pulled away
- Water stains at the head or sill inside
- Weep holes at the bottom of the frame that are clear
- Rubber gaskets that have shrunk away from corners
- Corrosion on framing near the sidewalk
Doors, Closers, and ADA Basics
Open the door and let it close on its own. It should close fully and latch, without slamming. The 2010 ADA Standards set a few measurable points worth knowing.
| Item | 2010 ADA Standard | Quick check |
|---|---|---|
| Closing speed | At least 5 seconds from 90 degrees open to 12 degrees | Count it with a phone timer |
| Opening force | 5 lb maximum for interior hinged doors | Heavy push? Ask for an adjustment |
| Threshold | 1/2 inch maximum, beveled above 1/4 inch | Check after winter heaving |
| Clear width | 32 inches minimum | Measure with the door at 90 degrees |
| Hardware | Usable without tight grasping or twisting | Try it with a closed fist |
Automatic Doors
Power-operated pedestrian doors are covered by the ANSI/BHMA A156.10 standard. The American Association of Automatic Door Manufacturers (AAADM) recommends a daily safety check by the owner and an annual inspection by an AAADM certified inspector.
A daily check is quick: walk through, make sure the door opens fully, stays open while you stand in the threshold, and closes smoothly. If it hesitates, bumps, or closes early, take it out of service. Our crew holds AAADM certification. See our automatic doors page.
Winter Items
Rinse salt off the lower frame and door bottoms when the weather allows. Salt left sitting all winter shortens the life of finishes and weatherstripping.
- Ice buildup at the threshold and the bottom of the door
- Snow piled against glass by plows or shovels
- Salt residue on door bottoms and framing
- Frozen locks or latches on cold mornings
- Condensation on vestibule glass when heat runs high
Energy and Comfort at the Front Door
Older storefronts often have single-pane glass in aluminum framing with no thermal break. That combination is cold to sit next to, sweats in winter, and runs up the heating bill for the front of the room. If staff near the windows wear coats in January, the storefront is part of the reason.
Replacing it with insulated glass in thermally broken framing is a bigger project, but it is often done in phases, starting with the entrance or the worst elevation. A vestibule with a second set of doors also cuts the cold air that rushes in every time the door opens.
Who Handles What, and How Often
| Task | How often | Who |
|---|---|---|
| Automatic door safety check | Daily | Staff |
| Walk the storefront with this list | Spring and fall | Owner or manager |
| Clear weep holes and rinse salt | Spring and fall | Staff or maintenance |
| Closer and hinge adjustment | When closing speed changes | Glass or door pro |
| Automatic door inspection | Annually | AAADM certified inspector |
When It Is Time To Call
Cracked glass, a door that will not latch, and water getting in are not wait-until-spring problems. For repairs, start on our commercial glass repair page. If the storefront is simply worn out, our storefronts page covers new framing, insulated glass, and entrances. Retail owners can also see glass for retail spaces.