Storefront Glass Checklist

Commercial · 6 min read

Your storefront works harder than any other part of the building. It takes wind off the lake, salt from the sidewalk, and a door that opens hundreds of times a day. Most failures start small: a closer that slams, a sealant joint that cracks, a threshold that ices up.

Walk the front of your building in spring and fall with this list. It takes about twenty minutes.

The Glass

An edge chip on tempered glass is worth a call. Tempered glass is strong across its face but vulnerable at the edge, and a chip there can turn into a full break.

  • Chips or cracks, especially at edges and corners
  • Fog or haze between panes of insulated glass
  • Scratches or etching from cleaning or vandalism
  • Peeling window film or old lettering adhesive
  • The small safety-glazing mark in the corner of door glass

Framing and Sealant

Aluminum storefront framing is built to let small amounts of water in and drain it back out through weep holes. When those holes clog with dirt or ice, water goes somewhere else, usually inside.

  • Sealant joints that are cracked, hard, or pulled away
  • Water stains at the head or sill inside
  • Weep holes at the bottom of the frame that are clear
  • Rubber gaskets that have shrunk away from corners
  • Corrosion on framing near the sidewalk

Doors, Closers, and ADA Basics

Open the door and let it close on its own. It should close fully and latch, without slamming. The 2010 ADA Standards set a few measurable points worth knowing.

Item2010 ADA StandardQuick check
Closing speedAt least 5 seconds from 90 degrees open to 12 degreesCount it with a phone timer
Opening force5 lb maximum for interior hinged doorsHeavy push? Ask for an adjustment
Threshold1/2 inch maximum, beveled above 1/4 inchCheck after winter heaving
Clear width32 inches minimumMeasure with the door at 90 degrees
HardwareUsable without tight grasping or twistingTry it with a closed fist

Automatic Doors

Power-operated pedestrian doors are covered by the ANSI/BHMA A156.10 standard. The American Association of Automatic Door Manufacturers (AAADM) recommends a daily safety check by the owner and an annual inspection by an AAADM certified inspector.

A daily check is quick: walk through, make sure the door opens fully, stays open while you stand in the threshold, and closes smoothly. If it hesitates, bumps, or closes early, take it out of service. Our crew holds AAADM certification. See our automatic doors page.

Winter Items

Rinse salt off the lower frame and door bottoms when the weather allows. Salt left sitting all winter shortens the life of finishes and weatherstripping.

  • Ice buildup at the threshold and the bottom of the door
  • Snow piled against glass by plows or shovels
  • Salt residue on door bottoms and framing
  • Frozen locks or latches on cold mornings
  • Condensation on vestibule glass when heat runs high

Energy and Comfort at the Front Door

Older storefronts often have single-pane glass in aluminum framing with no thermal break. That combination is cold to sit next to, sweats in winter, and runs up the heating bill for the front of the room. If staff near the windows wear coats in January, the storefront is part of the reason.

Replacing it with insulated glass in thermally broken framing is a bigger project, but it is often done in phases, starting with the entrance or the worst elevation. A vestibule with a second set of doors also cuts the cold air that rushes in every time the door opens.

Who Handles What, and How Often

TaskHow oftenWho
Automatic door safety checkDailyStaff
Walk the storefront with this listSpring and fallOwner or manager
Clear weep holes and rinse saltSpring and fallStaff or maintenance
Closer and hinge adjustmentWhen closing speed changesGlass or door pro
Automatic door inspectionAnnuallyAAADM certified inspector

When It Is Time To Call

Cracked glass, a door that will not latch, and water getting in are not wait-until-spring problems. For repairs, start on our commercial glass repair page. If the storefront is simply worn out, our storefronts page covers new framing, insulated glass, and entrances. Retail owners can also see glass for retail spaces.

Questions

Frequently Asked Questions

The 2010 ADA Standards set the 5 lb maximum for interior hinged doors. They do not set a number for exterior hinged doors, though local codes may. Closing speed, threshold height, clear width, and hardware rules apply either way.

Tempered glass is required in doors and many locations near them, and it breaks into small pieces. Laminated glass holds together when broken because of a plastic layer, which some owners prefer for security. We will talk through which fits each opening.

The Duluth Commercial Historic District is on the National Register, but National Register listing alone does not trigger city historic review. Locally designated properties are different. Check with the City of Duluth planning office if you are unsure which applies to your building.

We ask about your hours up front and tell you plainly what the work will disrupt and for how long.

Our team holds National Glass Association (NGA) certification and AAADM certification for automatic door work.

Get Started Today

Found Something On Your Walk?

Send us a photo or give us a call. We will tell you what it needs and put the price in writing.